Are you still worried about how to select the appropriate fans for your boiler system?
For boilers with a capacity above 2 t/h, forced draft (FD) and induced draft (ID) fans should generally be arranged per individual boiler. Depending on specific conditions, the fans may be installed either individually for each boiler or in a centralized arrangement.
Characteristics of individual (per-boiler) fan arrangement:
High flexibility. If one fan fails, it will not affect the operation of other boilers.
The forced draft and induced draft systems are relatively well sealed, resulting in less air leakage.
Better adjustment performance with changes in heat load, ensuring that the fans operate in an economical condition most of the time.
Larger floor area required and higher capital investment.
Characteristics of centralized fan arrangement:
The features are generally opposite to those listed above.
When adopting a centralized arrangement, the number of forced draft and induced draft fans should be determined according to actual requirements.
For boiler houses without special requirements, one forced draft fan and one induced draft fan can each be selected without standby units.
For facilities where production load accounts for a large proportion of the total load and continuous steam supply is frequently required, two forced draft fans and two induced draft fans can be installed.
Contact our official customer service, and Dajing will provide you with a free fan solution.
Trusted by industrial partners across 30+ countries — real feedback from our global clients.
“We’ve been using Dajing’s 9-19 high-pressure centrifugal blowers for our dust removal system. The airflow performance is excellent, and the noise level is much lower than our previous models. Truly reliable quality.”
Didn’t find the answer you were looking for?
Contact our engineering team for a customized solution.
Our engineers will recommend the suitable blower type based on your air volume, pressure, temperature, and working conditions.
You can also send your technical parameters or drawings directly for evaluation.
All Dajing blowers are ISO9001 and ISO14001 certified.
Depending on customer needs, we can also provide CE, EAC, or other international compliance certificates.
Yes. We offer fully customized blower systems to meet special environmental or industrial requirements, including high-temperature, dust-removal, and corrosion-resistant designs.
Generally 7-15 working days after receiving the deposit, depending on the order quantity and customization level.
Yes. We provide online technical guidance, spare parts supply, and on-site service if required.
Our goal is to ensure your blower operates efficiently throughout its service life.