How to Fix Recurring Oil Leaks in a Centrifugal Fan Bearing Housing?
Are you still struggling with recurring bearing housing oil leaks that waste lubricant and cause costly downtime?
In 90% of cases, the root cause comes down to these four issues:
- Seal failure – the most common cause. Worn or aged oil seals, excessive labyrinth seal clearance, or grooves worn into the shaft journal allow lubricating oil to escape.
- Lubrication system problems are also very common. An excessively high oil level, incorrect oil viscosity, or a blocked breather cap can create positive pressure inside the bearing housing, forcing oil out.
- Design or installation defects, such as a cracked housing, poor sealing at the joint surfaces, or excessive bearing clearance, can become long-term sources of leakage.
- Harsh operating conditions—including high temperatures, excessive vibration, or negative pressure drawing oil out—can accelerate seal failure and worsen leakage.
Different leak locations require different solutions. Identifying the exact source of the oil leak is the key to a permanent fix.
Customer Testimonials
Trusted by industrial partners across 30+ countries — real feedback from our global clients.
“We’ve been using Dajing’s 9-19 high-pressure centrifugal blowers for our dust removal system. The airflow performance is excellent, and the noise level is much lower than our previous models. Truly reliable quality.”
FAQ's
Didn’t find the answer you were looking for?
Contact our engineering team for a customized solution.
Our engineers will recommend the suitable blower type based on your air volume, pressure, temperature, and working conditions.
You can also send your technical parameters or drawings directly for evaluation.
All Dajing blowers are ISO9001 and ISO14001 certified.
Depending on customer needs, we can also provide CE, EAC, or other international compliance certificates.
Yes. We offer fully customized blower systems to meet special environmental or industrial requirements, including high-temperature, dust-removal, and corrosion-resistant designs.
Generally 7-15 working days after receiving the deposit, depending on the order quantity and customization level.
Yes. We provide online technical guidance, spare parts supply, and on-site service if required.